Shima Seiki

Free membership

Receive our weekly Newsletter
and set tailored daily news alerts.

Dyeing/​Finishing/​Printing

Monforts maintenance tips - the key to energy savings

20th March 2009, Monchengladbach – According to Monforts, over a period of ten years, the costs of energy (electricity, steam, gas) accounts for more than 60% of the initial investment of a finishing system. Skilled operation and regular maintenance of the Monforts system can subsequently reduce costs, the company says. This article is intended therefore to highlight simple tasks and tips to assist the machine operator to save energy whilst maintaining the high quality of fabric treatment.

20th March 2009

Knitting Industry
 |  Monchengladbach

Knitted Outerwear, Household, Technical Textiles

 

According to Monforts, over a period of ten years, the costs of energy (electricity, steam, gas) accounts for more than 60% of the initial investment of a finishing system. Skilled operation and regular maintenance of the Monforts system can subsequently reduce costs, the company says.

This article is intended therefore to highlight simple tasks and tips to assist the machine operator to save energy whilst maintaining the high quality of fabric treatment. It is important to know and understand the maintenance plan for the installation and only a system which is maintained regularly can provide full output with most economic input of energy.

The system’s lint filters should be inspected at least once every shift to ensure that they are clean and they must be cleaned with a brush or vacuumed if necessary.

The heat recovery modules also require cleaning at the prescribed intervals.  Soiled screens and heat exchangers reduce the output of the system substantially and increase the energy consumption.

Systems without Qualitex: the setting of the contact pressure of the padder should be within the working area of the diagram at the operator console  to ensure that the squeeze effect is uniform over the full width.

The more moisture that is removed and, the better it is removed, the less energy is required for drying.

Drying temperature range from 105º to 150ºC (depending on the fabric).  Material, finishing agents and methods determine the drying temperature.  The recommendations of the dyestuff and/or chemicals producers should be observed.  High drying temperatures not only consume too much energy, they often also damage the fabrics to be finished.

Pay attention to the optimum drying and heat-setting temperature.

An important aspect for good drying is to measure and control the exhaust moisture which is the moisture contained in the exhaust air of the dryer.

Depending on the fabric and the initial moisture, the optimum values are 10-20% by volume.  If the exhaust contains less moisture, too much fresh air is heated and energy wasted.  If the exhaust contains too much moisture, drying is poor; it takes more time and energy is wasted.

When drying is the only purpose, it is important to monitor the residual moisture - being the moisture contained in the fabric when it leaves the system.

The optimum residual moisture is measured with a humidity meter at the outlet of the dryer then controlled as needed.

Some examples of optimum residual moisture:

Co 6-8%

CV 8-10%

Wo 10-12%

PES 1-2%

PES/Co 2-4%

If the fabric is very dry, too much energy is wasted and drying is too expensive.  At the same time, production is unnecessarily slowed down.  Too little residual moisture also causes loss of quality.

Optimising the dwell time.  Depending on the fibre, the heatsetting of textiles requires a certain dwell time which must be observed to obtain the required fabric characteristics.

Usual dwell times

PES = 10 seconds at 185-200ºC (depending on fibre supplier)

Elasthane = 30-45 seconds at 185-195ºC (depending on fibre supplier)

All stenter frame chambers should have the required temperature for heatsetting.  To obtain the optimum production speed at the required dwell time, automatic control (Monformatic) is a necessity.  This will ensure the optimum production speed with minimum energy consumption.

Since heat setting is a process without exhaust moisture, the exhaust fan motor cannot be controlled by the exhaust air moisture meter.  The setting should be done manually to maintain a slight vacuum in the stenter.

Normally this exists at 50-60% exhaust capacity.  If the product tends to evaporate and the stenter emits smoke at the inlet and outlet openings, the speed of the exhaust fan motor should be increased until no smoke is emitted.

The lower the exhaust volume, the less energy is consumed.

If Thermat is fitted it should be set to 70-80ºC.  This ensures automatic control of the exhaust fan.

Setting time:  Is the heating time + dwell time

Heating time: Is the time to obtain the required dwell temperature

Dwell time:     Is the time the fabric remains in the machine after the heating time.

The speed of the air circulation fan motors should be adjusted as needed.  Higher speeds for heating, lower speed during dwell time.

Setting the air circulation fans (with stenters).

The Montex stenter is equipped with the TwinAir system where the flow rate for bottom and top air can be set separately.  Set the air circulation fans to ensure that the fabric ‘floats’ in the dryer without making contact.  Some common fan settings for maximum process speeds are illustrated.

Do not heat the system longer than is needed.  Do not hold the system at temperature without fabric longer than necessary.

Both waste energy and contaminate the environment.

Refurbishment

Monforts offer a variety of modification and extension kits for older systems.  If a heat recovery unit is service-fitted up to 30% of the energy needed for heating can be saved.

If the air circulation fans are fitted with modern frequency converters, the consumption of electricity can be drastically reduced.  And that with the shortest payback period you can imagine.

The Monforts soft-coating® method reduces the starting moisture.  This saves energy otherwise spent on drying or the production speed can be increased.

Online tele-service

Any machine downtime costs money.  Therefore, modern Monforts systems are serially shipped with online tele service.  This not only reduces the start-up time during the commissioning phase, it also ensures direct online assistance by the supplier if a problem occurs.  This ensures the shortest downtime, software updates and reprogramming and modernisation of machine controls.

Latest Reports

Business intelligence for the fibre, textiles and apparel industries: technologies, innovations, markets, investments, trade policy, sourcing, strategy...

Find out more